What KiCad's missing_courtyard rule means

drc:missing_courtyard is a real KiCad 9 rule identifier from the PCB Design Rules Checker. A footprint lacks an F.CrtYd or B.CrtYd outline for component placement and assembly clearance checking. The identifier is the stable part to use in reports, automation, and severity policy; the human-readable violation sentence can vary with the affected items and KiCad version.

The board can be manufactured, but automated collision/placement-density checks have incomplete library data.

Start from the marker’s exact items and coordinates. Cross-probe them in PCB Editor → Inspect → Design Rules Checker, then inspect the surrounding net, footprint, symbol, rule scope, hierarchy, or layer state. Do not begin by changing the global rule or adding an exclusion: that can hide the symptom while leaving the wrong connectivity, fabrication geometry, library data, or schematic intent in place.

KiCad rule IDmissing_courtyard
SourceDRC
Meaningfootprint has no courtyard
MakeIRL classS3
Explicitly recognizedyes
Primary editorPCB Editor → Inspect → Design Rules Checker

Why MakeIRL classifies it as S3

S3 ADVISORY: The board can be manufactured, but automated collision/placement-density checks have incomplete library data. MakeIRL still reports the evidence, but it does not affect the release decision.

Corpus evidence shows this on many working boards, so MakeIRL reports it as S3 library hygiene.

MakeIRL does not trust the severity label saved in a customer’s .kicad_pro. KiCad can be configured to ignore a rule entirely, so the gate authors a server-owned KiCad 9 reporting policy that forces the real catalog to be emitted and then applies its own rule-ID taxonomy. A project exclusion is recorded as evidence but never lowers the classification. Unknown identifiers also remain visible as S2 rather than disappearing or becoming an unjustified blocker.

S1 is reserved for evidence that a board is actually broken or assembly identity is impossible. S2 means a human engineering decision is required and can be acknowledged; it includes fab margins, many schematic conventions, parity drift, and rules whose intent depends on the product. S3 is advisory library, drafting, text, or silkscreen hygiene. This distinction explains why KiCad’s own “error” or “warning” word is evidence, not the release verdict.

How to fix missing_courtyard in KiCad 9

  1. 01

    Add a dimensioned closed courtyard to the controlled footprint library, update the board copy, and account for body, leads, and assembly allowance.

  2. 02

    Open PCB Editor → Inspect → Design Rules Checker, select the marker, and cross-probe every reported item before changing a rule or adding an exclusion. Fix the design or library source so the correction survives the next schematic/PCB update.

  3. 03

    Re-run DRC and compare the new courtyard with the component mechanical drawing and 3D body.

If the marker came from a library defect, repair the controlled symbol or footprint first and update the schematic/board copy deliberately. If it came from a net class or custom rule, confirm the electrical, timing, safety, or fabrication requirement before changing the number. A narrow, documented rule is safer than weakening the global project to make one marker disappear. For parity findings, compare the exact MPN, symbol pin numbers, footprint pads, BOM, and placement output before accepting either side as authoritative.

Verify the correction before release

Re-run DRC and compare the new courtyard with the component mechanical drawing and 3D body.

Save the corrected source files, refill zones when the board contains pours, and rerun the appropriate checker from a clean state. For PCB changes, inspect Gerber, drill, solder-mask, paste, outline, and placement outputs—not only the interactive canvas. For schematic changes, regenerate the netlist/BOM and run Update PCB from Schematic so stale board state cannot survive. Cross-probe the original coordinates and confirm the intended circuit or manufacturing constraint, not merely a zero marker count.

Finally, keep the original finding, the design change, and any remaining engineering acknowledgment in the release record. That gives reviewers a traceable reason why missing_courtyard is resolved, accepted as a deliberate S2 decision, or retained as an S3 advisory. Silencing the rule in project settings is never the fix because it changes reporting, not the board.