makeIRLPCB engineering field guide

KiCad 9 DRC & ERC rules

KiCad net_not_bus_member ERC: what it means and how to fix it

Understand KiCad 9's net_not_bus_member ERC rule, its MakeIRL S2 gate class, why it fires, and how to fix and verify it. Includes a practical KiCad repair.

Practical PCB integration · KiCad 9 · Manufacturing gate

What KiCad's net_not_bus_member rule means

erc:net_not_bus_member is a real KiCad 9 rule identifier from the Schematic Electrical Rules Checker. A scalar net label is used as though it belongs to a bus, but its name is absent from that bus's expanded member definition. The identifier is the stable part to use in reports, automation, and severity policy; the human-readable violation sentence can vary with the affected items and KiCad version.

The wire may fail to connect through the bus or indicate a misspelled member.

Start from the marker’s exact items and coordinates. Cross-probe them in Schematic Editor → Inspect → Electrical Rules Checker, then inspect the surrounding net, footprint, symbol, rule scope, hierarchy, or layer state. Do not begin by changing the global rule or adding an exclusion: that can hide the symptom while leaving the wrong connectivity, fabrication geometry, library data, or schematic intent in place.

KiCad rule IDnet_not_bus_member
SourceERC
Meaningnet is not a declared bus member
MakeIRL classS2
Explicitly recognizedyes
Primary editorSchematic Editor → Inspect → Electrical Rules Checker

Why MakeIRL classifies it as S2

S2 REVIEW REQUIRED: The wire may fail to connect through the bus or indicate a misspelled member. The finding is visible and must be acknowledged, but this rule alone does not prove the board is irreparably broken.

MakeIRL explicitly maps this naming/connectivity issue to S2.

MakeIRL does not trust the severity label saved in a customer’s .kicad_pro. KiCad can be configured to ignore a rule entirely, so the gate authors a server-owned KiCad 9 reporting policy that forces the real catalog to be emitted and then applies its own rule-ID taxonomy. A project exclusion is recorded as evidence but never lowers the classification. Unknown identifiers also remain visible as S2 rather than disappearing or becoming an unjustified blocker.

S1 is reserved for evidence that a board is actually broken or assembly identity is impossible. S2 means a human engineering decision is required and can be acknowledged; it includes fab margins, many schematic conventions, parity drift, and rules whose intent depends on the product. S3 is advisory library, drafting, text, or silkscreen hygiene. This distinction explains why KiCad’s own “error” or “warning” word is evidence, not the release verdict.

How to fix net_not_bus_member in KiCad 9

  1. 01

    Correct the scalar label, bus range/group definition, or alias so the net appears exactly once as a valid member.

  2. 02

    Open Schematic Editor → Inspect → Electrical Rules Checker, select the marker, and cross-probe every reported item before changing a rule or adding an exclusion. Fix the design or library source so the correction survives the next schematic/PCB update.

  3. 03

    Run ERC and highlight the member through the complete bus path.

If the marker came from a library defect, repair the controlled symbol or footprint first and update the schematic/board copy deliberately. If it came from a net class or custom rule, confirm the electrical, timing, safety, or fabrication requirement before changing the number. A narrow, documented rule is safer than weakening the global project to make one marker disappear. For parity findings, compare the exact MPN, symbol pin numbers, footprint pads, BOM, and placement output before accepting either side as authoritative.

Verify the correction before release

Run ERC and highlight the member through the complete bus path.

Save the corrected source files, refill zones when the board contains pours, and rerun the appropriate checker from a clean state. For PCB changes, inspect Gerber, drill, solder-mask, paste, outline, and placement outputs—not only the interactive canvas. For schematic changes, regenerate the netlist/BOM and run Update PCB from Schematic so stale board state cannot survive. Cross-probe the original coordinates and confirm the intended circuit or manufacturing constraint, not merely a zero marker count.

Finally, keep the original finding, the design change, and any remaining engineering acknowledgment in the release record. That gives reviewers a traceable reason why net_not_bus_member is resolved, accepted as a deliberate S2 decision, or retained as an S3 advisory. Silencing the rule in project settings is never the fix because it changes reporting, not the board.

Check the design before fabrication

Run the release gate and review net_not_bus_member with the rest of the KiCad evidence.

Check a KiCad project