KiCad 9 DRC & ERC rules
KiCad length_out_of_range DRC: what it means and how to fix it
Understand KiCad 9's length_out_of_range DRC rule, its MakeIRL S2 gate class, why it fires, and how to fix and verify it. Includes a practical KiCad repair.
Practical PCB integration · KiCad 9 · Manufacturing gate
What KiCad's length_out_of_range rule means
drc:length_out_of_range is a real KiCad 9 rule identifier from the PCB Design Rules Checker. A track/net length lies outside the minimum or maximum constraint set by a net class or custom rule. The identifier is the stable part to use in reports, automation, and severity policy; the human-readable violation sentence can vary with the affected items and KiCad version.
Length can control propagation delay, timing, loss, or topology, but the rule may also be a stale design target.
Start from the marker’s exact items and coordinates. Cross-probe them in PCB Editor → Inspect → Design Rules Checker, then inspect the surrounding net, footprint, symbol, rule scope, hierarchy, or layer state. Do not begin by changing the global rule or adding an exclusion: that can hide the symptom while leaving the wrong connectivity, fabrication geometry, library data, or schematic intent in place.
| KiCad rule ID | length_out_of_range |
|---|---|
| Source | DRC |
| Meaning | routed length out of range |
| MakeIRL class | S2 |
| Explicitly recognized | no — safe S2 fallback |
| Primary editor | PCB Editor → Inspect → Design Rules Checker |
Why MakeIRL classifies it as S2
This pinned rule uses the gate's unrecognized-rule fallback and therefore appears as visible S2 with recognized=false.
MakeIRL does not trust the severity label saved in a customer’s .kicad_pro. KiCad can be configured to ignore a rule entirely, so the gate authors a server-owned KiCad 9 reporting policy that forces the real catalog to be emitted and then applies its own rule-ID taxonomy. A project exclusion is recorded as evidence but never lowers the classification. Unknown identifiers also remain visible as S2 rather than disappearing or becoming an unjustified blocker.
S1 is reserved for evidence that a board is actually broken or assembly identity is impossible. S2 means a human engineering decision is required and can be acknowledged; it includes fab margins, many schematic conventions, parity drift, and rules whose intent depends on the product. S3 is advisory library, drafting, text, or silkscreen hygiene. This distinction explains why KiCad’s own “error” or “warning” word is evidence, not the release verdict.
How to fix length_out_of_range in KiCad 9
- 01
Use the length-tuning and net-inspection tools to shorten or add tuned meanders, remove stubs, or update the constraint from the interface timing budget.
- 02
Open PCB Editor → Inspect → Design Rules Checker, select the marker, and cross-probe every reported item before changing a rule or adding an exclusion. Fix the design or library source so the correction survives the next schematic/PCB update.
- 03
Re-run DRC and inspect total electrical path, including package/pad/via contributions the project intends to count.
If the marker came from a library defect, repair the controlled symbol or footprint first and update the schematic/board copy deliberately. If it came from a net class or custom rule, confirm the electrical, timing, safety, or fabrication requirement before changing the number. A narrow, documented rule is safer than weakening the global project to make one marker disappear. For parity findings, compare the exact MPN, symbol pin numbers, footprint pads, BOM, and placement output before accepting either side as authoritative.
Verify the correction before release
Re-run DRC and inspect total electrical path, including package/pad/via contributions the project intends to count.
Save the corrected source files, refill zones when the board contains pours, and rerun the appropriate checker from a clean state. For PCB changes, inspect Gerber, drill, solder-mask, paste, outline, and placement outputs—not only the interactive canvas. For schematic changes, regenerate the netlist/BOM and run Update PCB from Schematic so stale board state cannot survive. Cross-probe the original coordinates and confirm the intended circuit or manufacturing constraint, not merely a zero marker count.
Finally, keep the original finding, the design change, and any remaining engineering acknowledgment in the release record. That gives reviewers a traceable reason why length_out_of_range is resolved, accepted as a deliberate S2 decision, or retained as an S3 advisory. Silencing the rule in project settings is never the fix because it changes reporting, not the board.
Check the design before fabrication
Run the release gate and review length_out_of_range with the rest of the KiCad evidence.
Check a KiCad project→